Employing a common mode choke, line to ground and line to line capacitance enables attenuation of common and differential mode voltages (noise) from both lines on inputs and outputs of AC or DC systems in a single hermetically sealed package.
Part Number | Rated Voltage | Current | DCR Max Ohms /Line |
Mode |
Minimum Insertion Loss (dB) No Load 25°C | |||||||
DC | AC |
30 KHz |
100 KHz |
300 KHz |
1 MHz |
10 MHz |
100 MHz |
1 Ghz |
||||
51-875-003 |
200 | 130 | 1 | 0.250 | Comm | - | 11 | 28 | 50 | 60 | 70 | 65 |
Diff | 12 | 21 | 30 | 36 | 55 | - | - | |||||
51-875-004 | 200 | 130 | 3 |
0.025 |
Comm | - | 5 | 22 | 43 | 60 | 70 | 65 |
Diff | 12 | 21 | 30 | 36 | 55 | - | - | |||||
51-875-001 | 200 | 130 | 5 | 0.01 | Comm | - | - | 15 | 33 | 56 | 65 | 60 |
Diff | 9 | 18 | 27 | 35 | 50 | - | - | |||||
51-875-002 | 100 | - | 10 | 0.008 | Comm | 16 | 26 | 40 | 56 | 70 | 70 | 60 |
Diff | 20 | 30 | 39 | 49 | 58 | - | - |