Home | | | | DIN Rail Mounted Filters

DIN Rail Mounted EMI Filters

Power Filters

DIN Rail Mounted Single Phase EMI Power Filters make for easy connections, installations, and replacements. They provide excellent filtering characteristics that will combat both differential and common mode noise in EMC.

  • Low leakage current versions available
  • Chassis or DIN rail mount
  • High pulse or noise attenuation versions available
  • Easy connection and installation
  • RoHS compliant
  • Safety-agency approved
  • Epoxy molded for reliability
  • Medical: x-ray machine, bone mineral densitometer
  • Small electronic devices: printer, refrigerator, universal power supply, textile machinery, treadmill, electrical boiler
  • Control panel for electrical installation
  • Measuring and testing instruments
Operation Temperature Range -25 to +85°C including temperature Range
Storage Temperature Range -25 to +60°C
Insulation Resistance 300MΩ minimum at 500 VDC between line and ground
Model Voltage Rated Current
Max
Leakage Max
[250V,60Hz]
Volt. Drop
Max
Temp Rise
Max
L1+50 -30% CX1,2 20% CY1,2 [pF] 20% R1 10% [1/2W]
62-STB-06-5-14D 250VAC 6A 0.5mA 1.0V 45°C 14.0mH 0.47µF 3300pF 1.0MΩ
62-STB-10-4-14D 250VAC 10A 0.1mA 1.0V 45°C 5.7mH 0.47µF 470pF 1.0MΩ
62-STB-10-5-14D 250VAC 10A 0.5mA 1.0V 45°C 5.7mH 0.47µF 3300pF 1.0MΩ
62-STB-16-5-14D 250VAC 16A 0.5mA 1.0V 45°C 2.2mH 0.47µF 3300pF 1.0MΩ
62-STB-20-5-14D 250VAC 20A 0.5mA 1.0V 45°C 1.4mH 0.47µF 3300pF 1.0MΩ
62-STB-30-5-14D 250VAC 30A 0.5mA 1.0V 45°C 0.5mH 0.47µF 3300pF 1.0MΩ
*Also offered without din rail mount. Remove "D" from the part number when ordering.  
Model Voltage Rated Current
Max
Leakage Max
[250V,60Hz]
Volt. Drop
Max
Temp Rise
Max
L1+50 -30% CX1,2 20% CY1,2 [pF] 20% R1 10% [1/2W]
62-STB-06-5-13D 250VAC 6A 0.5mA 1.0V 45°C 4.2mH 0.33µF 3300pF 1.0MΩ
62-STB-10-5-13D 250VAC 10A 0.1mA 1.0V 45°C 1.7mH 0.33µF 3300pF 1.0MΩ
62-STB-16-5-13D 250VAC 16A 0.5mA 1.0V 45°C 0.8mH 0.33µF 3300pF 1.0MΩ
62-STB-20-5-13D 250VAC 20A 0.5mA 1.0V 45°C 0.35mH 0.33µF 3300pF 1.0MΩ
*Only offered on din rail mount.  
Model Voltage (AC) Rated Current
Max
Leakage Max
[500V,60Hz]
Operating Temp.
62-STB-6-3-13D 3Φ X 500V 6A 21.0mA max -25°C to +100°C
62-STB-6-3-14D 3Φ X 500V 6A 21.0mA max -25°C to +100°C
62-STB-10-3-13D 3Φ X 500V 10A 21.0mA max -25°C to +100°C
62-STB-10-3-14D 3Φ X 500V 10A 21.0mA max -25°C to +100°C
62-STB-16-3-13D 3Φ X 500V 16A 21.0mA max -25°C to +100°C
62-STB-16-3-14D 3Φ X 500V 16A 21.0mA max -25°C to +100°C
62-STB-20-3-13D 3Φ X 500V 20A 21.0mA max -25°C to +100°C
62-STB-20-3-14D 3Φ X 500V 20A 21.0mA max -25°C to +100°C
62-STB-30-3-13D 3Φ X 500V 30A 21.0mA max -25°C to +100°C
62-STB-30-3-14D 3Φ X 500V 30A 21.0mA max -25°C to +100°C
62-STB-40-3-13D 3Φ X 500V 40A 21.0mA max -25°C to +100°C
62-STB-40-3-14D 3Φ X 500V 40A 21.0mA max -25°C to +100°C