Spectrum Control, Inc.
ProductsSolutionsCompanyInvestor Relations    
 HomeSolutionsPerformance Testing
  "R" Level Testing
 

"R" level screening is performed by Spectrum Control's Hi-Rel Laboratory as detailed below. Customers requiring special tests may order to their own specifications or simply order to level R and then note additions or deviations.

 
 

"R" Level Test Sequence Summary



(100% testing unless otherwise specified)

  • Thermal Shock: 5 cycles from -55°C to +125°C in accordance with MIL-STD-202, Method 107D, Condition A.
  • Burn-in: 100 hours at 1.4x rated DC voltage, 125°C.
  • Seal Test: MIL-STD-202, Method 112, Test Condition A. Hermetic seal parts only.
  • Capacitance and Dissipation Factor: MIL-STD-202, Method 305, frequency 1kHz.
  • Dielectric Withstanding Voltage: 2.5 times the rated DC voltage for 5 ± 1 second at 25°C, with 50 mA maximum charging current.
  • Insulation Resistance: MIL-STD-202, Method 302, 125°C at rated DC voltage and room temperature (25°C). The 125°C requirement shall be 10% of the specified catalog IR at 25°C.
  • DC Resistance: MIL-STD-202, Method 303.
  • Insertion Loss Test — Sample per MIL-F-15733. At full rated load in accordance with MIL-STD-220. The minimum insertion loss shall be defined in the filter catalog.
  • Visual and Mechanical: in accordance with MIL-F-15733.
  • Marking: All filters which have successfully completed the test sequence shall be marked with an "R" in the second part of the number. For example, a standard SCI-2130-004 becomes SCI-R2130-004 and 9051-100- 0000 becomes 9051-R100-0000, and 51-719-011 becomes 51-R719-011 after completion of the Hi-Rel Level "R" Test Sequence.

Performance Tests

Class B Reliability Level Testing

 Contact the Quality Performance Testing Representative Contact a Quality Representative  

 
 
Home   ::   About Us   ::   Contact Us   ::   Partners   ::   Privacy Policy   ::   Terms & Conditions
 
Spectrum Sensors & Control spacer Spectrum Signal & Power Integrity spacer Spectrum Microwave Components & Systems spacer Spectrum Power Management Systems
 
Spectrum Sensors
& Controls
Spectrum Signal
& Power Integrity
Spectrum Microwave
Components & Systems
Spectrum Power
Management Systems
 
Spectrum Control, Inc.
Phone: 814-474-2207  ·  Fax: 814-474-2208
Copyright © 2007 Spectrum Control, Inc. All Rights Reserved